An AC that wasn't cooling in Winnetka: frost after the filter drier gave the restriction away
A Winnetka AC wasn't cooling. Frost on the copper after the filter drier, and none before it, showed a restriction. We pumped down and replaced the drier.
Straightforward guidance from working technicians: what things cost, what to try yourself, and when to call.
A Winnetka AC wasn't cooling. Frost on the copper after the filter drier, and none before it, showed a restriction. We pumped down and replaced the drier.
An AC in Northridge ran fine whenever we came out, then quit after long runs. Its blower motor was packed with dust. In Bel Air, a dusty motor burned out.
A Carrier side-discharge condenser near the ocean in Redondo Beach: a ruined coil, a fan that fell apart and rust all over. What salt air does to an AC.
A Granada Hills AC was overheating and cooling very poorly in July heat. Its condenser coil was caked with dust. Before and after a chemical cleaning.
An AC in the Hollywood Hills wasn't cooling. The condenser fan motor had burned out after its capacitor failed. How that happens and what to watch for.
On a Century City maintenance visit, the evaporator coil was packed with dust because the air filter hadn't been changed. Here's how we cleaned it.
A Fujitsu multi-zone mini-split with ducted ceiling units in West Hollywood was empty. We tested it, found and repaired the leak, evacuated and recharged it.
An attic furnace in Porter Ranch wouldn't start its igniter, yet the igniter itself was good. A new control board got the system working normally again.
A gas oven in Chatsworth wouldn't heat, or took very long to. We replaced the igniter. Here's how a weak igniter can glow and still keep the gas valve shut.
A gas water heater in Sherman Oaks flashed an error at its gas control valve. The chamber sensor's resistance had drifted, and a new sensor fixed it.
A ClimateMaster water-source heat pump in Hollywood was empty. We found the leak inside with nitrogen, brazed it on the spot and recharged it. It ran at once.
About a month after a new Goodman system was installed in Pacific Palisades, its condenser fan motor failed. We replaced it under the parts warranty.
A Goodman furnace in Burbank wasn't sensing its flame. The sensor is just a metal rod, so with it and its wiring ruled out, the control board was the fault.
Water was running from the ceiling under a fairly new Goodman package unit in Valley Village. Its plastic drain pan had a huge crack. Here's what it took.
A Lennox system in Brentwood burned out its compressor. With the new one running, suction pressure stayed far too low: the TXV was stuck closed.
Board or variable-speed blower motor? On a Lennox furnace in Woodland Hills, an ECM tester ran the motor on its own and showed the motor had failed.
A two-zone mini-split in San Fernando didn't cool after the owners moved in. The flare nuts at the outdoor unit were only hand-tight. Here's what we did.
An old R-22 AC in Van Nuys lost all its refrigerant where two copper lines rubbed through. We brazed it, pressure-tested the repair, evacuated and recharged.
A Samsung freezer in Chatsworth stopped freezing in hot weather, then seemed to recover. Its condenser coil was buried in dust. Before and after cleaning.
We replaced the light bulbs in a Sub-Zero refrigerator in Venice. What the photo shows, which bulbs Sub-Zero lists, and why a new bulb can stay dark.
Frost on a window AC's copper tubes while the blower runs points to low charge or a restriction. A Sun Valley case, and why the customer chose a new unit.
A Bosch dishwasher was leaking. The water came from the diverter motor under the tub; we replaced it and the leak stopped. What the photo shows, what to check.
A Bosch dishwasher took too long to drain and showed an error. The pump was fine: a piece of glass and debris were blocking the drain. Cleaning it fixed it.
A rooftop packaged AC unit at a medical clinic froze. We thawed it, added refrigerant and put in a new filter. What the photos show and what staff can check.
A Maytag washer showed a low water flow error. In diagnostic mode the cold water came in weakly. A new inlet valve fixed it. What to check before you call.
A Whirlpool side-by-side stopped making ice, and its ice maker wouldn't enter test mode. A new OEM ice maker dropped its first ice within about an hour or two.
A Whirlpool side-by-side stopped cooling. Its evaporator fan motor would start when pushed by hand, then quit. We defrosted the coil and replaced the motor.
A window air conditioner shut off as soon as it was switched on: the protection device in its plug had tripped. What that plug does and what to do if it trips.
A York AC condenser kept running and wouldn't turn off. A tap on the contactor released it: the contacts had welded together. We replaced the contactor.
A Daikin mini-split in Granada Hills smelled musty. The blower wheel had dried dust; the mold was in the drain pan. See how we foam-cleaned and rinsed it.
An LG washer showed OE and wouldn't drain. See the old and replacement pumps, what the comparison means, and what to check before replacing parts.
A glass-door cooler in Torrance froze its coil solid. A stuck relay in the controller kept the compressor running nonstop, with no defrost at all.
A heat pump in Santa Monica lost all its refrigerant. The leak was at the suction service valve, and the fix wasn't a new valve. It was cranked too tight.
A built-in KitchenAid refrigerator in Los Angeles stopped cooling. The inverter board flashed three blinks and the compressor never started. Here is the fix.
Ice returned after a recent defrost. See the upper-evaporator repair, the 15W heater used, and what we checked on this Samsung refrigerator.
A GE Profile had a working light and a blank display. See the swollen capacitors, rebuilt control board, and startup checks from this repair.
A KitchenAid dishwasher in Los Angeles filled and drained but the spray arms never turned. The circulation pump was seized by undissolved detergent pods.
A built-in KitchenAid refrigerator in the Los Angeles area stopped freezing. We found a refrigerant leak on the aluminum evaporator and replaced the coil.
A physical therapy clinic in Los Angeles had water dripping from the ceiling. The rooftop unit had no air filter, a choked evaporator coil and a blocked drain.
A frozen coil and a punctured copper tube on a Lennox rooftop package unit in Los Angeles. Brazed on-site, vacuum to 270 microns, cooling restored.
A brand-new HVAC system in Torrance lost its entire refrigerant charge after the installer used plumbing Teflon tape on the flare fittings.
A commercial TempStar dishwasher at a restaurant inside a Los Angeles movie theater had a burned control board. The universal replacement wasn't plug-and-play.
Three HVAC systems down at one Downtown LA restaurant: a drain-line problem, a failed capacitor and a refrigerant leak. One garage ceiling, three repairs.
One head on a Daikin mini split quit and the remote read J9. Most thermistors measured 28,000 ohms. One read 500. That comparison found the bad sensor.
A bar glasswasher ran water but the rack wouldn't turn. The motor drew current and sat still: seized gearbox. Two part numbers and the $1,100 repair math.
A backyard condenser lost its second compressor. The valve that killed both was still in the system, and the contactor was stuck too. American Standard, LA.
A Hollywood condo's ducted mini-split was losing R410A at a fitting hidden in the ceiling. We cut it out, brazed the line, and pulled a vacuum. Los Angeles.
A Viking built-in refrigerator kept losing refrigerant after a recharge. We traced the leak to the evaporator and replaced the coil. Los Angeles.
A nearly new LG WashTower needed a new door boot: the gasket was full of mold from a door kept shut after every cycle. The fix, and the habit that prevents it.
A bakery walk-in froze solid twice: setpoint far too low, no defrost cycle, a misleading sensor reading. Steam thaw and correct settings fixed it. Los Angeles.
A Fisher & Paykel DCS wall oven stalled at 200°F. The control board is discontinued — a component-level relay repair saved the oven. Los Angeles.
A rooftop condensing unit's compressor burned out completely. The warranty covered the part; the stuck TXV behind the failure is the real story.
A built-in KitchenAid kept pouring water onto the kitchen floor. Why the dispenser control panel corrodes, and why OEM parts matter — a real Los Angeles repair.
A 20-year-old built-in Sub-Zero lost all its refrigerant. How we found two leaks, hand-bent new copper and recharged the system by weight, in Los Angeles.
A nail salon's rooftop AC died and every quote said 'it's commercial.' What the repair really takes — motor, sheave, belt, coil — and how to spot fair pricing.
A brand-new 4-zone Daikin ran fine on day one, then locked out with UH and A5 codes. The installers had crossed the wiring — and the fix took no rewiring.
A pharmacy rooftop unit flashed 'high limit switch open.' Every switch tested fine — the real fault was cracked solder on the board. Repair beat a $400 swap.
We opened a dryer that hadn't been serviced in 15 years and found lint scorched black — it had started to burn. What annual dryer maintenance really involves.
How we diagnosed and replaced the failed compressor in an LG LFX25991ST that quit cooling in Santa Monica, and why a $1,300 repair beat a new fridge.
An old R22 AC came in completely empty. We traced the leak to the condenser coil — here's why a leaking R22 system needs a matched new unit, not a top-off.
What Bosch dishwasher error codes E15, E24, E22, E09 and E18 mean — causes, DIY checks, Bosch's E15 advice, and LA repair costs. Call (213) 205-2055.
Step-by-step guide to cleaning front and rear refrigerator condenser coils — including Sub-Zero grille units — and why LA heat makes it critical.
What LG washer codes IE, OE, UE, dE, FE and LE mean, likely causes, DIY checks to try first, and when to call a tech. Front-load and top-load. By Epic Star.
Samsung French-door ice maker freezing over or not making ice? Review likely causes, model-specific guidance, and when to arrange diagnosis.
What appliance repair actually costs in Los Angeles in 2026: fridge, washer, dryer, dishwasher, oven. Price ranges by issue and brand tier.
Dishwasher leaving residue or not cleaning? In LA, hard-water scale is a common cause. 5 causes, what to try yourself, and when to call a pro.
Dryer runs but won't heat? 4 common causes for gas and electric dryers, plus a critical fire-safety check most people skip. From LA technicians.
Oven won't heat or won't reach temperature? Causes for gas vs. electric ovens, plus Wolf/Viking/Thermador specifics. From LA technicians.
If your refrigerator stopped cooling, here are 7 common causes — from condenser coils to compressor failure — and how to tell which one you're facing.
The honest framework for deciding whether to repair or replace your refrigerator, washer, dryer, dishwasher, or oven. Age curves, brand tier, and the real math.
Estimated Sub-Zero repair cost factors by issue and model series. A diagnosis confirms the fault, parts, access, and written quote.
Washer won't drain water? 5 common causes, safe DIY steps to try, and when to call a professional. By Epic Star technicians.
When does it make sense to replace your refrigerator vs. repair? Age curves by brand tier, warning signs, energy savings math. From working LA technicians.